[Date Prev][Date Next]
[Chronological]
[Thread]
[Top]
Re: (ITS#5576) Missing attribute type 'managedInfo' referenced with SUP
h.b.furuseth@usit.uio.no wrote:
> ando@sys-net.it writes:
>> I suspect something like: if back-monitor and/or back-ldap are built as
>> modules, and loaded in the wrong order (back-ldap first, back_monitor
>> then), 'olmDbURIList' is likely to be registered __before__
>> 'managedInfo'.
>
> So, a manpage fix something like this?
>
> If monitor is a dynamically loaded module, it should be "moduleload"ed
> before any modules it wants to monitor. A dynamically loaded monitor
> may be unable to monitor a statically built module.
Not necessary. The order of moduleloads is irrelevant.
back-monitor initializes its schema as soon as the module is loaded. All of
the other backends initialize their monitor schema when a backend is first
instantiated. The problem you're talking about here doesn't exist.
--
-- Howard Chu
CTO, Symas Corp. http://www.symas.com
Director, Highland Sun http://highlandsun.com/hyc/
Chief Architect, OpenLDAP http://www.openldap.org/project/