[Date Prev][Date Next] [Chronological] [Thread] [Top]

Re: delta-syncrepl replica out of date

Francis Swasey wrote:
On 10/24/07 4:36 PM, Quanah Gibson-Mount wrote:

--On October 24, 2007 3:22:21 PM -0400 Francis Swasey <Frank.Swasey@uvm.edu> wrote:

Please post your configs.

They have changed very little since the first posting. Here they are though (as attachments)

Your "retry" setting looks strange. Can you fire up slapd with -d 64 (config file processing) and check:

"If an error occurs during replication, the consumer will attempt to reconnect according to the retry parameter which is a list of the <retry interval> and <# of retries> pairs. For example, retry="60 10 300 3" lets the consumer retry every 60 seconds for the first 10 times and then retry every 300 seconds for the next 3 times before stop retrying. The ‘+’ in <# of retries> means indefinite number of retries until success."

Yours is:


Kind Regards,

Gavin Henry.
OpenLDAP Engineering Team.

E ghenry@OpenLDAP.org

Community developed LDAP software.